SMARTBOX Installation
TURBINE JUNCTION BOX
EARTH
GROUND
STAKE
AC IN
TURBINE SMARTBOX™ Controller
12V
12V
12V
12V
12V
12V
OPTIONAL
TURBINE POLES
L1 N GND
AC OUTPUT
TO SUB SWITCH
BOARD
SINGLE PHASE
120V 15AMP
L1 N GND
AC INPUT
FROM MAIN SWITCH
BOARD
SINGLE PHASE
120V 15AMP
SEE TURBINE TO CONTROLLER SIZE
CHART ON SHEET 1
(2) #10 THWN-2 + #6 GND
¾” CONDUIT
MAX DISTANCE 3 FEET.
(2) #4 THWN-2 + #4 GND
1” CONDUIT
MAX DISTANCE 6 FEET.
(2) #12 THWN-2
+ #6 GND
¾” CONDUIT
(2) #12 THWN-2
+ #6 GND
¾” CONDUIT
CAT5E or CAT6
GRN/WHT
GRN
BRN/WHT
BRN
BLU/WHT
BLU
ORG/WHT
ORG
GRN/WHT
GRN
BRN/WHT
BRN
BLU/WHT
BLU
ORG/WHT
ORG
#4 GND
Wiring Diagram
Figure 2.4 Wiring Diagram
TURBINE TO CONTROLLER WIRE SIZE CHART
TURBINE WIRE MAX DISTANCE (FT) EMT CONDUIT (INCH)
#10 (#6 GND) 3/4
#8 (#4 GND) 1
150