1.5.6 OR / ORI (Connect NO contact in parallel / Connect NC contact in parallel)
OR (ORI) instruction connects a NO (NC) in parallel with another device or block.
OR instruction OR instruction OR instruction
1.5.7 ORP / ORF (Connect Rising edge in parallel/ Connect Falling edge in parallel)
Similar to OR instruction, ORP (ORF) instruction connects rising (falling) edge triggers in parallel
with another device or block
1.5.8 ANB (Connect block in series)
ANB instruction connects a block in series with another block
ANB command
1.5.9 ORB (Connect block in parallel)
ORB instruction connects a block in parallel with another block
ORB instruction
1.5.10 MPS / MRD / MPP (Branch instructions)
These instructions provide a method to create multiplexed output branches based on current result