A SERVICE OF

logo

© Adam Equipment Company 2011 Page
7
adjusted such that the bubble in the spirit level is in the centre of
the level and the scale is supported by all four feet.
AC powered scales, attach the power cable to the connector on
the bottom of the scale base. If using the external plug in power
supply module (USA) connect it to the socket on the side.
The power switch is located at the right side of the scale base.
The scale will show the model number in the Weight display
window (CBD 15, where 15 denotes the maximum capacity of the
scale in Kg) and the current software revision number in the “Unit
Weight” display window .
Next a self-test is followed. At the end of the self-test, it will
display “zero weight and zero values in all three displays. If the
weight display shows a value it was not possible to set a new
zero during power on.
SETTING UP THE REMOTE SCALE
The CBD Series can be connected to any size of load cell type
weighing base via the Remote scale port on the right side of the
scale case. Ensure you have the correct base for the scale as
each is matched for calibration.
Place the remote scale platform in the position where it is to be
used. Level the scale by adjusting the four feet. If fitted with a
spirit level then it should be adjusted such that the bubble is in the
centre.
Press [Local/Rem] to select the local scale or the remote base
for configuration and operation.