4.0 KEY DESCRIPTIONS
[0-9, •]
These keys are used to manually enter a value for tare weights, unit weight
and sample size. A secondary function is to enter alpha-numeric characters
for PLU descriptions etc.
[CE]
Pressing this key clears the unit weight or an erroneous entry. It also clears
the memory accumulation when the total is displayed.
[M+]
This key is used to add the current count to the accumulator. It also recalls
the memory when pressed with no load on the scale. Up to 99 values or full
capacity of the weight display can be added. Also prints the displayed values
when Auto print is switched off.
[Smpl]
This is used to enter the number of items of a sample.
[PLU]
To store and recall the Product Look Up sample information.
[U. Wt./Units]
This key is used to enter the weight of a sample manually. It will also change
the weighing units when other units are enabled.
[PST]
To set the upper limit for the number of items counted. When this upper limit
is exceeded the scale will sound the beeper. A secondary function is to use it
access the menus for user settings.
[Print]
It is used to print the weighing data.