Sega 4200-6367 Video Games User Manual


 
23
When INPUT TEST is selected, the MONITOR will show the following, allowing you to watch the status of
each switch and the value of each V.R.
7 - 6 INPUT TEST
FIG. 7.6 INPUT TEST
This test mode displays the status of each switch, button, and
Volu me. When the switch/button corrsponds to the name of
the item is pressed, if OFF changes to ON, it is satisfactory.
When corresponding Volume is operated, if the Volume value
differs in a natural manner, it is satisfactory.
APPROPRIATE VALUE OF TENSION VOLUME
Tension volume values are displayed in hexadecimal numer-
als within the range of 00H~ffH. If the value does not satisfy
the following limitations, adjust the Volumes gear mesh so as
to meet the requiremnts.
LOWER LIMIT: Over 05H
UPPER LIMIT: Under faH
Press the test button to return to the menu mode
INPUT TEST
HANDLEBAR OFF
THROTTLE OFF
FRONT BRAKE OFF
REAR BRAKE OFF
VIEW CHANGE OFF
MUSIC SELECT OFF
SHIFT UP OFF
SHIFT DOWN OFF
START OFF
COIN #1 OFF
SERVICE-SW OFF
TEST-SW OFF
PRESS TEST BUTTON TO EXIT
Choose OUTPUT TEST to cause the following lower screen
to appear. In this test, check the status of each lamp.
Pressing the TEST BUTTON causes “ON” to be
displayed and the corresponding lamp lights up.
Pressing the TEST BUTTON again cuases “OFF” to be
displayed and the lamp goes off. The Foot Controller is
locked with the Slide Lock in the ON status, and
Unlocked to become free with the Slide Lock in the
OFF status.
Press the test Button to return to the MENU MODE.
FIG. 7.7 OUTPUT TEST
7 - 7 OUTPUT TEST
OUTPUT TEST
START LAMP OFF
VIEW CHANGE LAMP OFF
MUSIC SELECT LAMP OFF
RACE READER LAMP OFF
>EXIT
SELECT WITH SERVICE BUTTON