Roland F-120R Video Game Keyboard User Manual


 
MIDI Implementation
33
020a: Flanger Delay
This e ect connects a  anger and a delay in series.
No Parameter Value Description
1
Flanger Pre
Delay
0–125 0.0–100.0 ms
Adjusts the delay time from
when the direct sound begins
until the  anger sound is
heard.
2
Flanger Rate
Mode
0–1 Hz, note
When this is set to “note,” the
e ect is synchronized with the
tempo.
3 Flanger Rate 1–127
0.05–10.00
Hz
Frequency of modulation (Hz)
4 Flanger Rate 0–21 note
Frequency of modulation
(note)
5
Flanger
Depth
0–127 0–127 Depth of modulation
6
Flanger
Feedback
0–98 -98–+98%
Adjusts the proportion of the
anger sound that is fed back
into the e ect. Negative (-)
settings will invert the phase.
7
Flanger
Balance #1
0–100
D100:0W–
D0:100W
Volume balance between
the direct sound (D) and the
 anger sound (W)
8
Delay Time
Mode
0–1 ms, note
When this is set to “note,” the
e ect is synchronized with the
tempo.
9 Delay Time 0–127 1–2540 ms
Adjusts the delay time from
the direct sound until the
delay sound is heard. (ms)
10 Delay Time 0–21 note
Adjusts the delay time from
the direct sound until the
delay sound is heard. (note)
11
Delay
Feedback
49–89 0–+80%
Adjusts the proportion of the
delay sound that is fed back
into the e ect.
12
Delay HF
Damp
0–17
200–8000 Hz,
Bypass
Adjusts the frequency above
which sound fed back to
the e ect will be cut. If you
do not want to cut the high
frequencies, set this parameter
to Bypass.
13
Delay
Balance #2
0–100
D100:0W–
D0:100W
Adjusts the volume balance
between the sound that is
sent through the delay (W)
and the sound that is not sent
through the delay (D).
14 Level 0–127 0–127 Output Level
020b: Chorus Flanger
This e ect connects a chorus and a  anger in series.
No Parameter Value Description
1
Chorus Pre
Delay
0–125 0.0–100.0 ms
Adjusts the delay time from
the direct sound until the
chorus sound is heard.
2
Chorus Rate
Mode
0–1 Hz, note
When this is set to “note,” the
e ect is synchronized with the
tempo.
3 Chorus Rate 1–127
0.05–10.00
Hz
Modulation frequency of the
chorus e ect (Hz)
4 Chorus Rate 0–21 note
Modulation frequency of the
chorus e ect (note)
5
Chorus
Depth
0–127 0–127
Modulation depth of the
chorus e ect
6
Chorus
Balance #1
0–100
D100:0W–
D0:100W
Volume balance between
the direct sound (D) and the
chorus sound (W)
7
Flanger Pre
Delay
0–125 0.0–100.0 ms
Adjusts the delay time from
when the direct sound begins
until the  anger sound is
heard.
No Parameter Value Description
8
Flanger Rate
Mode
0–1 Hz, note
When this is set to “note,” the
e ect is synchronized with the
tempo.
9 Flanger Rate 1–127
0.05–10.00
Hz
Modulation frequency of the
anger e ect (Hz)
10 Flanger Rate 0–21 note
Modulation frequency of the
anger e ect (note)
11
Flanger
Depth
0–127 0–127
Modulation depth of the
anger e ect
12
Flanger
Feedback
0–98 -98–+98%
Adjusts the proportion of the
anger sound that is fed back
into the e ect. Negative (-)
settings will invert the phase.
13
Flanger
Balance #2
0–100
D100:0W–
D0:100W
Adjusts the volume balance
between the sound that is
sent through the  anger (W)
and the sound that is not sent
through the  anger (D).
14 Level 0–127 0–127 Output Level