5 - 110
MELSEC-Q
5 DATA USED FOR POSITIONING CONTROL
5.7 List of control data
5.7.1 System control data
Setting item Setting details
Cd.1
Flash ROM write request
•
Requests writing of data (parameters, positioning data, and block start data) from
the buffer memory to the flash ROM.
•
Requests initialization of setting data.
Initialization: Resetting of setting data to default values
Note: After completing the initialization of setting data, reset the PLC CPU or reboot
the PLC power.
Initialized setting data
Parameters (
Pr.1
to
Pr.57
,
Pr.150
)
Positioning data (No. 1 to No. 600)
Block start data (No. 7000 to 7004)
Cd.2
Parameter initialization request
Cd.41
Deceleration start flag valid
Set whether "
Md.48
Deceleration start flag" is made valid or invalid.
Cd.42
Stop command processing for
deceleration stop selection
•
Set the stop command processing for deceleration stop function (deceleration
curve re-processing/deceleration curve continuation).