6
3.3 Power supply specifications
Specifications
Item
A975GOT-TBA(-B)
A970GOT-TBA(-B)
A970GOT-SBA
A970GOT-LBA
A960GOT-EBA
A975GOT-TBD(-B)
A970GOT-TBD(-B)
A970GOT-SBD
A970GOT-LBD
A960GOT-EBD
Input power supply
voltage
100AC to 240V (+10%,-15%) 24VDC(+25%,-20%)
Input frequency [Hz]
50/60 ± 3
-
Input max. apparent
power
Using 100VAC
Communication board loaded:
50VA or less
Communication module loaded:
60VA or less *1
Using 200VAC
Communication board loaded:
63VA or less
Communication module loaded:
75VA or less *1
-
Input max. power - 40W
Inrush current
40Ap max.
(264VAC, max. load)
61Ap max.
(30VDC, max. load)
Permissible
instantaneous power
failure time
20ms (100VAC or more) 1ms (19.2VDC or more)
Noise immunity
By noise simulator of 1,500Vp-p
noise voltage, 1
μ
s noise width and
25 to 60Hz noise frequency
By noise simulator of
500Vp-p noise voltage,
1
μ
s noise width and 25 to
60Hz noise frequency
Dielectric withstand
voltage
1500VAC for 1 minute across AC
external terminals and earth
500VAC for 1 minute
across DC external
terminals and earth
Insulation resistance
10MΩ or larger by insulation resistance tester
Applicable wire size 0.75 to 2mm
2
Applicable solderless
terminal
RAV1.25–3, V2–S3.3, V2-N3A, FV2-N3A
Applicable tightening
torque (Terminal block
terminal screw)
59 to 88Nycm
External output Refer to *2
*1: When the communication module for bus connection (A9GT-BUSSU/A9GT-
BUS2SU/A9GT-QBUS2SU) is loaded, this value is equivalent to the input
max. apparent power value when the communication board is loaded.
*2: For external outputs please refer to the A985GOT/A975GOT/A970GOT/
A960GOT User’s Manual that is to be purchased separately.
Remarks
Note that the power is reset if an instantaneous power failure occurs.
However, if the instantaneous power failure is within 20ms when using 100
to 240VAC, or within 1ms when using 24VDC, the operation will be normal.