33
Operation
SMARTBOX™ Controller for HONEYWELL™ Wind Turbine WT6500 Owner’s Manual - Rev14
1. This is the home screen. The SMARTBOX™ Controller will scroll the listed
informationwhileinrunmodeandalsothecurrentrmwarerevision.
2. Turbine Fault Stop. Indicates if a fault has occurred.
3. This is the top menu level. From here you can go to the TECHNICIAN MENU or the
START/STOP TURBINE MENU. Pressing enter to make a selection.
4. The Start/Stop Turbine Menu. Pressing UP will place the SMARTBOX™ Controller
in user stop mode. In this mode the turbine will not spin and no A/C will be produced.
Pressing DOWN will start the turbine. This will start a battery charge cycle.
Technician Menu
.TECHNICIAN
..FORCE CHARGE ?
.TECHNICIAN
..FORCE AC ?
UP/DWN
UP/DWN
.TECHNICIAN
..CLEAR PRODUCTION ?
UP/DWN
ENTER/BACK
ENTER/BACK
ENTER/BACK
.TECHNICIAN
..VIEW DATA ?
VIEW DATA
MENU
UP/DWN
ENTER/BACK
..FORCE CHARGE
UP=START
..START CHARGE
UP=START
..CLEAR PRODUCTION
UP/HOLD=CLEAR
.TECHNICIAN
..BATTERY SETUP ?
UP/DWN
BATTERY SETUP
MENU
ENTER/BACK
1
2
3
4
5
Figure 4.6 Technician Menu
1. Force Charge. This forces the turbine into the bulk charge state to begin charging the
batteries.
2. Force AC. This turns on the inverter and switches the transfer switch to turbine AC. It
alsoswitchestheturbinemodeintooatcharge.
3. Clear production. This clears the Watt-Hour productions values in the turbine both
turbine and AC productions values.
4. View Data. Selecting view data moves a menu level down to the view data menu.
5. Battery Setup. Selecting battery setup moves a menu level down to the battery setup
menu.