18
| P a g e © Adam Equipment Company 2011
6.6 ACCUMULATED
TOTAL
• The scale can be set to accumulate manually by pressing the
[Print/M+/Esc] key or automatically when a weight is removed
from the scale. See the Section 7.3 for details of setting the
Parameter “C3 PRM” and “C4 Aon”. The accumulation function is
available when weighing or when counting parts. However the
memory is cleared if the weighing units or functions are changed.
• When the weight (or count) displayed is stored in memory the
display will show “ACC 1” and then the total in memory for 2
seconds before returning to weighing. The RS-232 interface will
output to a printer or PC.
• Remove the weight, allowing the scale to return to zero and put a
second weight on. When this value is stored, the display will
show “ACC 2”, then the new total and finally the value of the
second weight. Repeat as necessary to add all the values needed
to the memory.
• To view the total in memory press the [Print/M+/Esc] key when
there is no weight on the scale. The display will show the number
of entries and the total.
• To clear the memory (set the value to zero) press the [Func/C]
key during the time the totals are being displayed.