© Adam Equipment Company 2009
13
6.8
USER
CALIBRATION
FUNCTION
•
Press [Hold/
] to switch on or off the function.
•
"OFF CAL": the user calibration function is off.
•
"ON CAL": the user calibration function is enabled.
•
Press the [Tare/
↵
↵↵
↵
] key to confirm the setting and enter the next setting.
It enters unit setting when it shows "On g " or "OFF g".
6.9
SELECTION
OF
WEIGHING
UNITS
Each weighing unit can be set to be either on or off. If it is on it is available when the
user presses the [Units/
] key during normal weighing. If it is off the weighing unit
is not available during normal use. The grams unit is always on.
•
Press the [Hold/
] key to change the unit from on to off.
•
On: the unit is enabled.
•
Off: the unit is disabled.
•
The units will be in the following sequence: "Kg" / "lb" / "oz"/"CUS".
•
If the custom unit “CUS” is enabled, press [Tare/
↵
↵↵
↵
] to confirm the
setting and go on to set the relation between g and customer unit. The
value can be set from 0.00001 to 9.99999.
•
Press [Func/
] to select the flashing digit;
•
Press [Units/
] to decrease the value;
•
Press [Hold/
] to increase the value;
•
Press the [Tare/
↵
↵↵
↵
] key to confirm and move back to the first setting.
Turn the scale off and on again to enter the normal weighing mode and save the
changes make.