4. Press the RECHARGE button to move the softener into fast rinse. Again look for a fast drain
flow. Allow the softener to rinse for a few minutes to flush out any brine that may r emain in the
resin tank from the brining cycle test.
5. To return the softener to service, press the RECHARGE button.
Manual Advance Diagnostics --- Model WHES30
Use the following pr ocedures to advance the wa ter softener through the regeneration cycles to check
operation.
Liftoff thesaltholecover,r emovethe topcover byunlocking the tabsin the backand rocking forward,
to observe cam and switch operation during valve rotation.
1. Press and hold
PROGRAM for 3 seconds until 000 -- -- shows in the display.
2. The first 3 digits indicate w ater meter operation as follows:
000 (steady) = Soft water not in use, and no flow through the meter.
Open a nearby soft water faucet.
000 to 199 (continual) = Repeats display for each gallon of water passing through the meter.
NOTE: If you don’t get a reading in the display, with faucet open, pull the sensor from the valve
outlet port. Pass a small magnet back and forth in front of the sensor. You should get a
reading in the display. If you geta reading, unhookthe in andout plumbing and check the
turbine for binding.
3. Symbols in the display indicate POSITION switch operation.
Switch is open
(cam not rotating)
Switch is closed
(Cam rotating)
4. Use the RECHARGE button tomanually advance thevalve intoeach cycleand check correct
switch operation.
NOTE: Be su re water isin contactwith thesalt,and n otseparated by asaltbridge... see “Breaking
A Salt Bridge” section.
5. While in this diagnostic screen, the following information is available and may be beneficial for
various reasons. This information is retained by the computer from the first time electrical power
is applied to the face plate.
Press
+
Up to display the number of days this electronic control has had electrical
power applied.