6
Parallel
Fan-Powered
VAV-SLM005-EN CONFIDENTIAL DOCUMENT. FOR INTERAL USE ONLY.
Product
Features
Green = Trane is advantaged
Yellow = Trane is equal
Red = Trane is disadvantaged
Trane vs. Price Page
Valve/fan combinations ...................................................................................... 13, 16
Lower damper leakage ............................................................................................ 13
More measuring point on our flow ring ................................................................8, 13
Water coil access is
standard with hot water reheat ................................................. 13
Air filter ................................................................................................................8, 13
Filter frame ...........................................................................................................8, 13
Fan disconnect.....................................................................................................8, 13
Hanger brackets ...................................................................................................8, 13
Manual secondary cutout for electric reheat .........................................................9, 13
Factory-commissioned DDC controls ......................................................................11
Electric heat wire type ............................................................................................. 14
Perforated liner ................................................................................................... 11, 13
SCR electric heat control .....................................................................................11, 14
120-volt electric heat ................................................................................................ 14
kW range .................................................................................................10, 13, 30–31
Fan cfm range ............................................................................................... 14, 18–21
Attenuators ............................................................................................................. 14
Price
FDV, FEV, FPV
5 fan sizes available, 220–2900 (range based on .25 in. wg DSP)
14 valve/fan combinations
Factory calibrated to job requirements
SP-200 multi-point flow sensor with 12 measuring points
DDC, Analog, or Pneumatic control options
Options include hot water coils or integral electric coils for reheat, attenuators, and
various insulation
Trane
VPCF, VPWF, and VPEF
7 fan sizes available, 210–2500 cfm (range based on .25 in. wg DSP)
19 valve/fan combinations
Minimum 14 measuring point flow ring
Metal encapsulated insulation edges standard for IAQ
Rugged contractor tough unit construction
Factory-commissioned controls
Factory calibrated
UL and ARI listed
Factory-mounting customer controls availability
DDC, Analog, or Pneumatic control options
Options include hot water coils or integral electric coils for reheat, attenuators, and
various ‘IAQ’ linings