JP01 ON =
Delay between shutdown and re-ignition disabled
JP01 OFF =
Delay between shutdown and re-ignition enabled
JP02:
Jumper on for natural gas
Jumper on for LPG
JP03 ON = Max temperature D.H.W. 62°C
JP03 OFF= Max temperature D.H.W. 55°C (standard)
Potentiometer adjustment
P1 = Central heating flow temperature adjustment
P2 = Domestic hot water temperature adjustment
P3 = Central heating flow output adjustment
P4 = Ignition gas pressure adjustment
P5 = Minimum adjustment pressure
9. ELECTRICAL AND FUNCTIONAL SCHEME
9.01 Main components layout on electronic boards
temp. Ohm
10 °C 20 kOhm
25 °C 10 kOhm
60 °C 2,5 kOhm
80 °C 1,25 kOhm