ICE·49
Cable
Card
The cable card is included for cable driving. It transmits
address
and
data bus information to the user system
through a
40·pin connector which plugs into the user
system
in
the socket designed for the MCS·48 device.
Software
The
ICE·49
software driver
Is
a RAM·based program
which provides the user with
an
easy to use command
language (see Table
1,
Table
2,
and
Table
3)
for defining
breakpoints, initiating
real·time emulation or single step
operation,
and
interrogating
and
altering user system
status recorded during emulation.
The
ICE·49
command
language contains a broad range
of
modifiers to provide
the user with maximum
flexibility in defining the opera·
tion to
be
performed.
The
ICE·49
software driver is
available on diskette
and
operates in
32K
of Intellec
RAM
memory.
Command
Operation
Enable Activates breakpOint
and
display regis·
ters for use with go
and
step com·
mands.
Go Initiates
real·time emulation
and
allows
user to specify breakpoints and data
retrieval.
Step
Initiates
emulation in single instruction
Increments.
Each
step is followed by
register dump.
User may
optionally
tailor other diagnostic activity to his
needs.
Interrupt
Emulates user system interrupt.
Table
1.
ICE·49 Emulation Commands
SPECIFICATIONS
ICE·49 Operating Environment
Required Hardware
Intellec microcomputer development system
System console
Intellec diskette operating system
ICE·49 Module
Required
Software
System
monitor
ISIS·II
Equipment Supplied
Printed circuit boards (control board, emulator board)
Interface cables
and
buffer module
ICE·49 software, diskette·based version (single density
or double density)
8048 with internal monitor program
Command
Operation
Display Prints contents
of
memory,
MCS·48
device registers,
1/0
ports, flags, pins,
real·time trace data, symbol table, or
other diagnostic data
on
list device.
Change Alters contents of memory, register,
output port, or flag.
Sets or alters break·
pOints
and
display registers.
Map
Defines memory status.
Base
Establishes mode of display for output
data.
Suffix Establishes mode
of
display input data.
Table
2.
ICE·49 Interrogation Commands
Command Operation
Load
Fetches user symbol table
and
object
code from input device.
Save
Sends user symbol table
and
object
code to output device.
Define
Enters symbol name
and
value to user
symbol table.
Move Moves block of memory data to another
area of memory.
list
Defines list device.
Exit Returns program control to
ISIS·II.
Evaluate Converts
expression
to
equivalent
values in binary, octal, decimal, and
hex.
Remove
Deletes symbols from symbol table.
Reset
Reinltiallzes
ICE·49
hardware.
Table
3.
ICE·49 Utility Commands
System Clock
Crystal controlled
6.0
MHz internal,
3.0
MHz internal or
user supplied TTL external: software selectable.
Physical Characteristics
Width -
12.00
In.
(30.48
cm)
Height -
6.75
in.
(17.15
cm)
Depth - 0.50 in.
(1.27
cm)
Weight -
8.00
lb.
(3.64
kg)
Electrical Characteristics
DC
Power Requirements
Vee
=
+5V
±5%
lee = 10A mal(; 7.0A typ
Voo
= +
12V
±5%
100 =
79
mA max;
45
mA typ
Vss =
-10V
±5%
Iss =
20
mA max
10-16