Trane N512 Video Game Controller User Manual


 
Index
40 CNT-SVX07C-EN
Electric heat, 1
Face-and-bypass dampers, 1
Outdoor/return air dampers, 1
Rover service tool, 1
Tri-state modulating dampers, 1
Tri-state modulating valves, 1
Two-position valves, 1
Current-sensing switches, 4
D
Dampers
Actuators, 5
Exhaust, 41
Face-and-bypass, 1, 21, 46
Modulating outdoor/return air,
43, 46
Outdoor/return air, 1, 21, 41, 43
Supported applications, 1, 21
Tri-state modulating, 1
Two-position control, 46
Data sharing, 48
Dehumidification, 47
Device addressing for BAS
communication, 9
Diagnosing operational problems,
63–67
Diagnostics
Automatic, 58
Clearing, 58
CO2 Sensor Failure, 60
Condensate Overflow, 59
Discharge Air Temp Failure, 60
Discharge Air Temp Limit, 60
Entering Water Temp Failure, 60
Freeze protection, 60
Generic AIP Failure, 61
Generic Temperature Failure, 61
Humidity Input Failure, 60
Informational, 59
Invalid Unit Configuration, 61
Latching, 58
Local Fan Mode Failure, 61
Local Setpoint Failure, 61
Low Coil Temp Detection, 59
Maintenance (filter change), 59
Manual, 58
Nonlatching, 58
Normal, 61
Outdoor Air Temp Failure, 60
Smart reset, 59
Table, 59
Types, 58
Zone Temp Failure, 59
Dimensional diagram, 3
Dimensions, 2
Discharge air temperature
Failure diagnostic, 60
Low limit diagnostic, 60
Discharge air temperature input, 18
Discharge air temperature low limit,
50
Discharge air tempering, 39
DX cooling
Operation, 46
Supported application, 21
Troubleshooting, 65
E
Economizing, 19, 45
Electric heat
Operation, 47
Supported application, 21
Troubleshooting, 65
Entering water temperature
Diagnostic, 60
Input, 17
Sampling function, 40
Equipment supported, 1, 13, 21
Exhaust control, 41
F
Fan
Exhaust, 41
Mode input, 17
Operation, 40
Supply, 41
Troubleshooting, 63
Fan coils, 1, 21
Fan off delay, 49
Fan status
Input, 15
Switching devices, 4
Unit protection, 49
Filter-maintenance timer, 50
Four-pipe operation, 43
Free cooling,
see Economizing
Freeze avoidance, 19, 50
Freeze protection, 50
Freeze-protection switch, 4, 14
G
Generic
Binary input, 15
Binary output, 59
Temperature input, 18
Generic AIP failure diagnostic, 61
Generic binary input, 15
Generic binary output, 21
Generic temperature failure
diagnostic, 61
H
Heating or cooling mode, 39
Humidity
Input failure diagnostic, 60
Measurement input, 20
Zone sensor, 20
Hydronic cooling, 21
I
Informational diagnostics, 59
Input/output functions, 13–34
Input/output terminal wiring, 7
Invalid unit configuration
diagnostic, 61
Isolation valve operation, 46
L
LEDs
General, 51
Interpreting green (status), 57
Interpreting red (service), 56
Interpreting yellow
(communications), 57
Location, 51
Local fan mode input failure
diagnostic, 61
Local setpoint failure diagnostic, 61
Local setpoint input, 17
LonTalk communication
Description, 1
Termination resistors, 9
Wiring and addressing, 9
LonTalk protocol,
see LonTalk
communication