20 Operating and Maintaining the P20 Console
Event
Number
Description of Event
22 No motor pulses at start up
23 Motor pulses missing after start up
24 Reduce speed requested, speed is not reducing
26 Motor pulse width incorrect
27 Too much drive motor current
28 Temperature too high
29 Excessive AC input current
30 Communications event lower board to upper board
31 Incorrect Communications event upper board to
lower board
32 Communication event upper board to lower board
33 Incorrect communications event lower board to
upper board
40 Lift motion detected
42 Lift position value out of range
43 Zero switch not found
44 Un-commanded lift motion
45 Lift going in the wrong direction
50 Too much brake (magnet) current
53 Cannot read target, cannot find home switch
54 Target pulses lost during operation
55 Brake home switch activated unexpectedly
60 Auto Stop sensor failure (treadmill)
61 Auto Stop not present (treadmill)
Hour Meter
Tracks the number of hours that a piece of equipment has
run. The equipment also tracks elapsed minutes, but the value
that displays is rounded up the nearest full hour.