Fluke 110 Video Game Keyboard User Manual


 
Models 110, 111 & 112
Users Manual
12
Accuracy ± ( [ % of Reading ] + [ Counts ] )
Function Range Resolution Model 110 Model 111 Model 112
AC Volts
1,2
-- True RMS
(50 Hz to 500 Hz)
6000 mV
3
6.000 V
60.00 V
600.0 V
1 mV
0.001 V
0.01 V
0.1 V
1.0 % + 3 1.0 % + 3 1.0 % + 3
DC Volts 6000 mV
3
6.000 V
60.00 V
600.0 V
1 mV
0.001 V
0.01 V
0.1 V
0.7 % + 2 0.7 % + 2 0.7 % + 2
Continuity 600 1 Beeper guaranteed on < 20 , guaranteed off > 250 ; detects
opens or shorts of 250 µs or longer.
Ohms 600.0
6.000 k
60.00 k
600.0 k
6.000 M
40.00 M
0.1
0.001 k
0.01 k
0.1 k
0.001 M
0.01 M
0.9 % + 2
0.9 % + 1
0.9 % + 1
0.9 % + 1
0.9 % + 1
1.5 % + 3
0.9 % + 2
0.9 % + 1
0.9 % + 1
0.9 % + 1
0.9 % + 1
1.5 % + 3
0.9 % + 2
0.9 % + 1
0.9 % + 1
0.9 % + 1
0.9 % + 1
1.5 % + 3
Diode test 2.200 V 0.001 V 0.9 % + 2
1.9 % + 2
1.9 % + 2
1.9 % + 2
1.9 % + 2
1.9 % + 2
1.9 % + 2
1.9 % + 2
1.9 % + 2
1.9 % + 2
Capacitance
4
1000 nF
10.00 µF
100.0 µF
10000 µF
1 nF
0.01 µF
0.1 µF
1 µF
100 µF - 1000 µF: 1.9% + 2
> 1000 µF: 10% + 90 typical
AC Amps
5
-- True RMS
(50 Hz to 500 Hz)
(Models 111 and 112)
10.00 A continuous or
20 A overload for 30
seconds maximum
0.01 A NA 1.5 % + 3 1.5 % + 3