Making Basic Measurements
The figures on the following pages show how to make basic
measurements.
When connecting the test leads to the circuit or device, connect
the common (COM) test lead before connecting the live lead;
when removing the test leads, remove the live lead before
removing the common test lead.
Warning
To avoid electric shock, injury, or damage to the Meter,
disconnect circuit power and discharge all high-voltage
capacitors before testing resistance, continuity, diodes,
or capacitance.
Note
In reading AC voltage or current, for the integrated RMS
converter to correctly measure distorted waveforms, reading
settling time increases to several seconds at the low end of
AC voltage and current ranges.
The Meter is not specified for use with current clamp
accessories.
Measuring AC and DC Voltage
Volts DC Volts AC
V
V
aej03f.eps