Standard Commands for Programmable Instruments (SCPI)
113
ARPS/SCPI Commands
Table C-6 lists the ARPS commands and compares them with the equivalent SCPI commands recognized by the
Agilent series 603xA power supplies. Note that the Agilent Series 603xA power supplies use only a subset of SCPI
commands. Use the SYST:LANG command to change between the two languages.
Note See Table 3-7 in Section III for command parameter ranges and Table 3-6 for the initial turn-on values.
Table C-6. Comparison of ARPS and SCPI Commands
ARPS Equivalent ARPS Equivalent ARPS Equivalent
Command SCPI Command Command SCPI Command Command SCPI Command
ASTS? STAT:OPER? ID? *IDN? STO *SAV
STAT:QUES? ISET x CURR STS? STAT:OPER:COND?
*ESE? ISET xv STAT:QUES:COND?
CLR *RST ISET xMV *ESE?
DLY x OUTP:PROT:DEL ISET? CURR? SYST:LANG SYST:LANG
DLY xS IOUT? MEAS:CURR? SYST:LANG? SYST LANG ?
DLY xMS IMAX x (none) T INIT ON;TRIG
DLY? OUTP:PROT:DEL? IMAX xv TRG INIT ON;*TRG
ERR? SYST:ERR? IMAX xMV TEST? *TST?
FAULT? STAT:OPER:ENAB? IMAX? UNMASK STAT:OPER:ENAB
STAT:QUES? OUT OFF OUTP:STAT OFF STAT:QUES:ENAB
*ESE? OUT 0 OUTP:STAT 0 *ESE
FOLD OFF (none) OUT ON OUTP:STAT ON UNMASK? STAT:OPER:ENAB?
FOLD 0 OUT 1 OUTP:STAT 1 STAT:QUES:ENAB?
FOLD CV OUT? OUTP:STAT? *ESE?
FOLD 1 OVP’ VOLT:PROT? VSET x VOLT
FOLD CC VSET xv
FOLD 2 VSET xMV
FOLD? VSET? VOLT?
HOLD OFF (none) RST OUTP:PROT:CLE VOUT? MEAS:VOLT?
HOLD 0 RCL *RCL VMAX x (none)
HOLD CV SRQ OFF *SRE VMAX xv
HOLD 1 SRQ 0 VMAX xMV
HOLD CC SRQ ON VMAX?
HOLD 2 SRQ 1
HOLD? SRQ? *SRE?