5
1
2
Reset the high temperature limit stop:
Turn the water off at the stops. Push the handle to
the full up position (1). Loosen the handle screw 4
complete turns with a 4 mm allen wrench (2). Pull off
the handle (3) and the nut cover.
Turn the stem so that the handle screw faces forward.
3
Remove the handle screw (1). Pull off the high tem-
perature limit stop (2).
Reinstall the high temperature limit stop so that the pin
on the cartridge goes through the hole for the desired
high temperature.
The temperatures shown on the illustration assume
an incoming cold water temperature of 50
o
F, and an
incoming hot water temperature of 140
o
F.
Test the faucet. If the high temperature is still too hot,
reposition the high temperature limit stop.
Replace the nut cover (1). Replace the handle screw
and tighten it 4 complete turns.
Replace the handle (1). Finish tightening the handle
screw (2). Install the screw cover (3)