—25—
CONDENSER ONLY RATINGS*
See notes on page 26.
SST
°F
CONDENSER ENTERING AIR TEMPERATURES °F
55 65 75 85 95 105 115 125
561C018-A, D
30
TCG 17.6 16.2 14.7 13.4 12.0 10.7 9.52 8.35
KW 1.37 1.49 1.58 1.66 1.73 1.77 1.80 1.82
SDT 75.6 86.1 96.4 106.0 116.0 126.0 136.0 146.0
35
TCG 19.6 18.1 16.6 15.1 13.6 12.3 10.9 9.68
KW 1.40 1.52 1.63 1.73 1.81 1.87 1.91 1.93
SDT 76.5 87.2 97.4 107.0 117.0 127.0 137.0 146.0
40
TCG 21.8 20.1 18.5 16.9 15.4 13.9 12.5 11.1
KW 1.42 1.56 1.68 1.79 1.88 1.96 2.01 2.05
SDT 77.6 88.4 98.6 109.0 119.0 128.0 138.0 147.0
45
TCG 24.1 22.3 20.6 18.9 17.2 15.6 14.1 12.6
KW 1.44 1.59 1.73 1.85 1.96 2.05 2.12 2.17
SDT 78.7 89.7 100.0 110.0 120.0 130.0 139.0 149.0
50
TCG 26.5 24.6 22.7 20.9 19.1 17.4 15.8 14.2
KW 1.46 1.62 1.77 1.91 2.03 2.14 2.22 2.29
SDT 79.8 91.0 102.0 112.0 122.0 131.0 141.0 150.0
55
TCG 29.0 27.0 25.0 23.1 21.2 19.4 17.6 15.9
KW 1.47 1.65 1.82 1.97 2.10 2.22 2.32 2.40
SDT 81.1 92.3 103.0 113.0 123.0 133.0 142.0 152.0
561C024-A, D
30
TCG 22.5 20.9 19.2 17.5 15.9 14.2 12.6 11.0
KW 1.83 1.95 2.05 2.14 2.21 2.26 2.29 2.29
SDT 70.0 82.2 93.6 104.0 115.0 125.0 135.0 145.0
35
TCG 24.9 23.2 21.5 19.7 17.9 16.2 14.5 12.8
KW 1.89 2.01 2.13 2.23 2.32 2.38 2.43 2.45
SDT 69.8 82.6 94.2 105.0 116.0 126.0 136.0 145.0
40
TCG 27.5 25.7 23.8 22.0 20.1 18.3 16.5 14.6
KW 1.94 2.08 2.21 2.32 2.42 2.50 2.57 2.60
SDT 69.5 82.9 95.0 106.0 117.0 127.0 137.0 146.0
45
TCG 30.1 28.3 26.3 24.4 22.4 20.5 18.5 16.6
KW 2.00 2.15 2.29 2.42 2.53 2.63 2.70 2.76
SDT 69.7 83.2 95.6 107.0 118.0 128.0 138.0 148.0
50
TCG 32.9 31.0 29.0 26.9 24.8 22.7 20.7 18.7
KW 2.07 2.22 2.37 2.51 2.64 2.75 2.84 2.91
SDT 70.3 83.4 96.3 108.0 119.0 129.0 139.0 149.0
55
TCG 35.8 33.8 31.8 29.6 27.3 25.1 23.0 20.9
KW 2.13 2.29 2.45 2.60 2.74 2.87 2.98 3.07
SDT 70.9 83.8 97.0 109.0 120.0 131.0 141.0 151.0
561C030-A, D
30
TCG 28.0 26.0 24.0 22.0 20.1 18.2 16.4 14.7
KW 2.21 2.35 2.48 2.61 2.72 2.82 2.91 2.98
SDT 77.5 87.5 97.4 107.0 117.0 127.0 136.0 146.0
35
TCG 31.1 28.9 26.7 24.6 22.6 20.6 18.6 16.8
KW 2.29 2.44 2.59 2.72 2.85 2.97 3.07 3.15
SDT 78.9 88.9 98.8 109.0 118.0 128.0 137.0 147.0
40
TCG 34.3 32.0 29.7 27.4 25.2 23.1 21.0 18.9
KW 2.38 2.54 2.70 2.85 2.99 3.11 3.23 3.33
SDT 80.5 90.6 100.0 110.0 120.0 129.0 139.0 148.0
45
TCG 37.7 35.2 32.8 30.4 28.0 25.7 23.4 21.2
KW 2.47 2.64 2.81 2.97 3.12 3.27 3.40 3.51
SDT 82.1 92.3 102.0 112.0 121.0 131.0 140.0 150.0
50
TCG 41.3 38.7 36.1 33.5 31.0 28.5 26.1 23.7
KW 2.56 2.75 2.92 3.10 3.27 3.42 3.57 3.70
SDT 83.9 94.0 104.0 114.0 123.0 133.0 142.0 151.0
55
TCG 45.1 42.3 39.5 36.8 34.1 31.4 28.8 26.3
KW 2.66 2.86 3.05 3.23 3.41 3.58 3.74 3.89
SDT 85.8 96.0 106.0 116.0 125.0 135.0 144.0 153.0
561C036-A, B, D, E
30
TCG 32.1 30.5 28.9 27.2 25.5 23.7 21.8 19.9
KW 2.33 2.57 2.84 3.11 3.40 3.68 3.95 4.21
SDT 78.6 89.0 99.3 109.0 120.0 129.0 139.0 149.0
35
TCG 35.2 33.5 31.8 30.0 28.2 26.3 24.3 22.3
KW 2.40 2.65 2.92 3.21 3.51 3.81 4.10 4.39
SDT 79.9 90.4 101.0 111.0 121.0 131.0 141.0 150.0
40
TCG 38.4 36.7 34.9 33.0 31.0 29.0 26.9 24.8
KW 2.47 2.72 3.00 3.30 3.61 3.93 4.25 4.56
SDT 81.3 91.9 102.0 112.0 123.0 132.0 142.0 152.0
45
TCG 41.8 40.0 38.1 36.1 34.0 31.8 29.7 27.4
KW 2.55 2.81 3.10 3.40 3.73 4.06 4.40 4.74
SDT 82.9 93.5 104.0 114.0 124.0 134.0 144.0 154.0
50
TCG 45.4 43.5 41.5 39.3 37.1 34.9 32.5 30.2
KW 2.63 2.90 3.19 3.51 3.84 4.20 4.55 4.91
SDT 84.6 95.3 106.0 116.0 126.0 136.0 146.0 155.0
55
TCG 49.2 47.2 45.0 42.8 40.4 38.0 35.5 33.0
KW 2.72 2.99 3.29 3.62 3.97 4.33 4.70 5.08
SDT 86.4 97.0 107.0 118.0 128.0 138.0 148.0 157.0