Sega Zombie Revenge Video Game Console User Manual


 
29
11. TROUBLESHOOTING
PROBLEMS CAUSE COUNTERMEASURES
With Main SW Power is not supplied. Plug in correctly
ON, no activation
Power supply/voltage is not correct. Make sure that power supply/voltage is
correct
Irregular sound Greasing to gear mesh portion is not Apply greasing or eliminate extraneous
emitted from satisfactory, or extraneous matter matter.
inside Cabinet mixed in.
The color of the Connector connections are defective. Check the connection for the RGB and
image on PROJ. SYNC connectors of the PROJ. TERM.
screen is incorrect. BD and VPM BUFFER BD.
The image on PROJ. Affected by the magnetic field of Make CONVERGENCE adjustment.
screen has color installation location. (Refer to Section 12.)
deviation.
No sound is emitted. Sound Volume adjustment is not Adjust sound volume. (see Section 7).
appropriate.
Sound BD and speaker are Perform sound test to find and replace
malfunctioning. defective parts.(Refer to Section 7).
*NETWORK check Communication cable’s connection Perform V.R. setting, Adjustment.
will not finish. failure.
*Communication play Communication cable’s connection Check for Communication cable
is not possible. failure. disconnection
Communication Play setting is wrong. Correctly set in test mode.
Should trouble occur, first check connector connections.