Graco 3A2097B Video Game Controller User Manual


 
Installation (Model 24H989)
3A2097B 3
Installation (Model
24H989)
The intrinsically safe flow control module (FC) is
required to use flow control in your system. It is for use
with a remotely mounted, air-operated fluid regulator
(FR, not included). See F
IG. 2.
1. Connect a 1/4 in. (6 mm) OD air supply line to the
air inlet fitting of the flow control module (FC). Con-
nect the other end of this line as follows:
a. Wall Mount Systems: Connect to the air mani-
fold at the rear of the wall mount fluid station.
b. RoboMix Systems: Install a 1/4 in. (6 mm) OD
tube tee at the air logic inlet of the RoboMix.
Connect the flow control air line to one branch
of the tee and the main air line to the other
branch.
2. Connect a 5/32 in. (4 mm) OD air supply line to the
air outlet fitting of the flow control module (FC). Con-
nect the other end of this line to the air inlet fitting of
a remotely mounted fluid regulator (FR).
3. Connect a fluid line from the proportioner to the fluid
inlet of the remote fluid regulator (FR).
4. Connect a fluid line from the outlet of the fluid regu-
lator (FR) to the 1/8 npt(f) inlet of the pressure sen-
sor (PS).
5. Connect a fluid line from the 1/8 npt(f) outlet of the
pressure sensor (PS) to the spray gun inlet.
6. Connect the pressure sensor cable to the cable con-
nector on the flow control module (FC).
7. See the Electrical Schematic in your ProMix
instruction manual. Connect the flow control cable to
the fluid station control board and to the cable con-
nector on the flow control module (FC).
F
IG. 2. 24H989 Flow Control Module, with Remotely Mounted Fluid Regulator
262376_1
FC
FR
Fluid to Pressure Sensor
Air to Flow Control
Air to Fluid Regulator
Fluid to Fluid Regulator
Fluid to Gun
Flow Control Cable
PS
From Proportioner From Proportioner