Connecting the Power
1. Attach a ground cable to the ground screw on the printer.
2. Connect the cable from the power supply to J8.
3. Connect the power cable to the line outlet.
4. Apply power to the printer.
If you use another type of power supply unit, connect the voltages according to the following
illustration.
At the printer end of the cable, use a Tyco Mate-N-Lok connector housing and two
contact-sockets:
Figure 9 • Power Connection
Caution • Use only the recommended Zebra power supply (see Part Number List
on page 124
for part number).
Important • The ground and the 24 V ground must be separated in the power supply to avoid
ground loops!
Tyco No. 350777-1 Tyco No. 350689-1
Table 5 • Current Consumption at Factory Default Settings
Print Density TTP 8200 TTP 8300
None (Idle) 0.15 A 0.15 A
10% coverage 1 A 2 A
20% coverage 2 A 3 A
30% coverage 3 A 4 A
40% coverage 4 A 5 A
50% coverage 5 A 6 A
All black printing 10 A 12 A
Note • Print speed, burn time, and temperature affects these values.