FOR THE PLUMBER
CONNECT TO WATER
SUMP PUMP
(observe local -codes)
1
Use
114”
OD soft copper tubing for the cold water
supply.
2 Provide a convenrent manual shut-off valve In the
water line.
3 Position the tub’
rng so it can enter the access hole
located in the right-hand rear of the cabinet. The
tubing should extend beyond the cabinet front
when the cabinet is pushed back into position. See
Figure 5.
NOTE:
Always purge the water line before making the final
connection to the inlet of the water valve to prevent
possible water valve malfunction.
After the cabinet is in place, bend the tubing to meet
the connection at the water valve. The garden hose
threaded compression fitting is found in the parts
bag. This joint provides a convenient disconnect for
service. Be sure the tubing is clear of compressor, to
prevent rattle.
CONNECT THE DRAIN
(observe local codes)
1
The unit IS provided with a gravtty drain.
2 The Ideal Installation has a standpipe
(llf4”
mlnrmum) Installed directly below the outlet of the
drain tube. Refer to Figure 5 for the proper location
of the standpipe.
3 It may be desirable to insulate drain line thoroughly
up to dram inlet.
1
When a drain connectlon below the level of the unit
IS not avallable. a sump pump may be used to Irft
the water to an avarlable drain
2 Install sump pump on floor behind ice maker with
discharge tube to the rear. Run bin drain directly
Into sump pump as shown In the Illustration.
NOTE:
Electric connection to sump pump should be from a
circuit that remains energized continually.
FIELD SUPPLIED
WATER LINE
THRU THIS HOLE.
RIGHT END VIEW
3/4.*-j +- 23.7/8”-1
d
I
WATER INLET ’
SOLENOID ;
VALVE
I
1/4”O.D. WATER
LINE COMPRESSION
VALVE
BEND FIELD SUPPLIED WATER LINE
TO CONNECT TO WATER VALVE FITTING
BACK VIEW
t- I
17.7/8”-
FIGURE 5
RUBBER
--- ..UN TO
IRAIN
FOR FIELD
ED WATER
3’
I
4