A SERVICE OF

logo

Reelmaster 5010 Series Page 3 -- 9 Kubota Diesel Engine
Removal (Fig. 3)
1. Park machine on a level surface, lower cutting units,
stop engine, engage parking brake and remove key
from the ignition switch. Raise hood.
2. Remove air cleaner components as needed using
Figures 3, 4 and 5 as guides.
3. See Traction Unit Operator’s Manual for air cleaner
service and maintenance procedures.
Installation (Fig. 3)
IMPORTANT: Any leaks in the air filter system will
allow dirtinto engineand will cause serious engine
damage. Make sure that all air cleaner components
areingood conditionand areproperly secured dur-
ing assembly.
1. Assemble air cleaner system using Figures 3, 4 and
5 as guides.
A. If indicator and adapter were removed from air
cleaner housing, apply thread sealant to adapter be-
fore ins talling adapter and indicator to housing.
B. Make surethat vacuator valveis pointeddown af-
ter assembly.
Figure 4
1. Air cleaner assembly
2. Mounting band
3. Adapter
4. Indicator
5. Hex nut
6. Hose clamp
7. Hose
8. Spacer
9. Hose
10. Hose
11. Hose clamp
12. Bolt
13. Spring
REELMASTER 5610--D
12
6
11
8
5
10
13
9
4
1
3
2
7
11
6
Figure 5
1. Mounting band
2. Cover
3. Vacuator valve
4. Adapter
5. Indicator
2
3
4
1
5
Kubota Diesel
Engine