![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/b/83/b830cecd-eea5-41b9-b860-c37d968f495b/b830cecd-eea5-41b9-b860-c37d968f495b-bg69.png)
Standards Compliance for SNMP Traps
B-5
7986-A2-GB20-00
September 1998
The tests that affect the enterpriseTestStart, enterpriseTestStop, and the
variable-bindings are different for each particular interface. Diagnostic tests are
only supported on the physical E1 network and user data port interfaces. The
specific tests and variable-bindings are described in the following table:
Interface
enterpriseTestStart/Stop
Variable-Bindings
Possible Cause
HDSL
Network
H ifIndex (RFC 1573)
H ifAdminStatus (RFC 1573)
H ifOperStatus (RFC 1573)
H ifType (RFC 1573)
H ifTestType (RFC 1573)
The following objects control tests
in SNMP-managed devices:
– noTest – Stops the test in
progress.
– testLoopLLB – Initiates a Local
Loopback.
– testLoopRLB – Initiates a
Remote Loopback.
– testSendMon511 – Initiates a
Send and Monitor 511 test.
– testSendLLBUp – Initiates an
LLB Up message to the remote
unit.
– testSendLLBDown – Initiates an
LLB Down message to the
remote unit.
H enterpriseTest Start – Any
one of the following tests is
active on the interface:
– Line Loopback
– Payload Loopback
– Repeater Loopback
– Remote Line Loopback
– Send and Monitor 511
H enterpriseTest Stop – No tests
currently running on the
interface.
G.703 H ifIndex (RFC 1573)
H ifAdminStatus (RFC 1573)
H ifOperStatus (RFC 1573)
H ifTestType (RFC 1573)
The following objects control tests
in SNMP-managed devices:
– noTest – Stops the test in
progress.
– testLoopExternalDTE