6 NAVMAN S100 User Manual
• Connect the red wire to the positive supply
via a 1 amp fuse or a 1 amp circuit breaker.
Connect the black wire to the electrical
ground. A 1 amp fuse will provide protection
for up to five 100 series instruments.
• Connect the 4 pin Fuji connector to the
speed and temperature transducer cable
connector. Extension cables are available if
the transducer cable is too short.
• If you are not using a repeater or you do
not intend to provide NMEA data to another
instrument then insulate the bare wire end
of the blue cable.
Wiring Connection
• Keep electrical and transducer cables away
from alternator or other noise generating
electrical cables. Avoid connecting the
instrument to power circuits that share
loads with ignition, alternators, inverters and
radio transmitters. Electrical power supply
connections should always be as short as
possible.
Black
Blue
Red
1A Fuse
+12 VDC
Ground
NMEA output to repeater
Fuji
Plug &
Socket
Speed
Transducer
Green
Black
Blue
Red
Black
Blue
Red
1A Fuse
+12 VDC
Ground
NMEA speed data to repeater
NMEA data to Wind
NMEA wind data to repeater
Fuji
Plug &
Socket
Wind
Transducer
Speed
Transducer
Multiple Instruments
The NAVMAN S100 may be used
as an individual instrument or
connected with a number of other
100 series instruments to the 100
series repeater or to other
instruments accepting NMEA
0183 data.