3-8
29. Choose the height of the antenna above the water surface and then press the C:
ENTER soft key.
30. Choose STC CURVE and then press the C: EDIT soft key.
STC CURVE
▲
{
NARROW
~
NORMAL
{
WIDE
▼
31. Choose appropriate STC curve setting and then press the E: RETURN soft key.
NARROW: The effective range of the A/C SEA adjustment is relatively short.
NORMAL: Between NARROW and WIDE.
WIDE: The effective range of the A/C SEA adjustment is relatively long.
32. If you are going to use the equipment as a remote display, choose MONITOR
MODE and then press the C: EDIT soft key. If not, go to step 34.
MONITOR MODE
▲
{
ON
~
OFF
▼
33. Choose ON and then press the C: ENTER soft key.
• TX blanking function is not available when the MONITOR MODE is ON. To set a TX
blanking sector, select OFF from MONITOR MODE on the NavNet equipment, and
then set the sector same as the main radar. Finally, set MONITOR MODE to ON.
• When the MONITOR MODE is ON, the following functions are not available.
• Tuning (auto/manual, on the RADAR SETUP menu)
• Antenna rotation (RADAR SETUP menu)
• TX sector blanking (RADAR DISPLAY SETUP menu)
• Watchman (RADAR DISPLAY SETUP menu)
• Pulse select (Soft key)
34. Choose HEADING ADJUST and then press the C: EDIT soft key.
HEADING ADJUST
▲
{ ON
~ OFF
▼