AutoDome Easy Connections 5
Bosch Security Systems, Inc. Installation and Configuration Manual December 06, 2006 | F01U032279
4.4 Alarm
The recommended optional alarm input cable is a 2-conductor, 18-22 gage cable, depending
on the distance. Refer to the wiring distance guide Table 4.1 on page 5.
Table 4.1 Wiring Distance Guide
5 Connections
Follow the instructions below to terminate all connections as described.
Table 5.1 Connection Cable Description
5.1 Connecting to the Biphase
The AutoDome Easy camera can be controlled remotely by an external device or control sys-
tem, such as a control keyboard, using biphase.
5.1.1 Direct Control
To connect the biphase configuration, do the following:
1. Locate the cable assembly with a two (2) pin black mating connector on one end and the
brown and black flying leads on the other end.
2. Connect the biphase+ from the controller to the black lead and secure.
3. Connect the biphase- from the controller to the brown lead and secure.
4. Connect shield of the cable to the Head End controller.
Fig. 5.1 Biphase Direct Control
Wire Size Maximum Distance
AWG mm feet meters
22 0.644 500 152.4
18 1.024 800 243.8
Color Description
Black Biphase (+)
Brown Biphase (-)
Red AC24 V / DC12 V
Orange AC24 V / DC12 V
Blue ALARM COMMON
Violet ALARM IN
C-
C+
SHIELD
Head End
Biphase
Brown
Black
Not Connected X
AutoDome Easy