![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/5/59/55999827-4619-4362-9a69-d2906caff226/55999827-4619-4362-9a69-d2906caff226-bg4c.png)
68 | Accessories for Control Panels and Keypads | Expansion Modules
DX2010 Series Input
Expander
Features
▶
Up to eight sensor input loops
▶
Directly connects to the control panel data bus
The DX2010 Input Expander connects directly to the data
bus of a compatible control panel. Each expander adds
eight input loops. Install up to five expanders in a control
panel's enclosure (three on the interior sidewalls and two
on the back wall of the enclosure).
Certifications and Approvals
Region Certification
Europe CE DX2010: 1999/5/EC, 2006/95/EC,
2004/108/EC; EN 55022:2006 +
A1:2007, Class B; EN 50130-4 w/
A1:1998 + A2:2003;
EN61000-3-2:2006;
EN61000-3-3:1995; EN 60950-1:2001;
TBR21:1998
Belgium INCERT DX2010 and DX2012 only
USA UL DX2010: AMCX: Central Station Alarm
Units (UL1610, UL1635), AMTB: Control
Panels, SIA False Alarm Reduction, AOTX:
Local Alarm Units (UL464, UL609), APAW:
Police Station Alarm Units (UL365,
UL464), APOU: Proprietary Alarm Units
(UL1076), NBSX: Household Burglar
Alarm System Units (UL1023), UTOU:
Control Units and Accessories - Household
System Type (UL985)
CSFM DX2010: 7167-1615: 183 and
7167-1615: 223 July 2008
France AFNOR NF, A2P Type 2 (122000076-03)
Installation/Configuration Notes
Compatibility Information
Control Panels Easy Series (ICP‑EZM2‑NA, ICP‑EZM2‑UK,
ICP‑EZM2‑LC), D4412, D6412, DS7220V2, and
DS7240V2
Technical Specifications
Outputs
Outputs: 100 mA, 12 VDC supervised output for acces-
sories
Environmental Considerations
Operating Temperature: 0°C to +50°C (+32°F to +122°F)
Relative Humidity: 5% to 85% at +30°C (+86°F), non‑condensing
Loop
Inputs: Up to eight inputs
Input contacts may be normally‑open (NO) or
normally‑closed (NC) with appropriate end-of-
line resistor(s) for supervision.
Resistance: 60Ω maximum
Terminal Wire Size: 1.8 mm (14 AWG) to 0.8 mm (22 AWG)
Power Requirements
Current (Maximum): 35 mA standby
35 mA maximum with connected accessories
Voltage (Operating): 8 VDC to 14 VDC
Ordering Information
DX2010 Input Expander
Provides hard-wired expansion for an addi-
tional eight input points. Includes the DX2010
board.
DX2010
DX2011 Package
Includes a DX2010 Input Expander with a
D203 Metal Enclosure.
DX2011
DX2012 Package
Includes a DX2010 Input Expander with an
AE20 Plastic Enclosure.
DX2012
Accessories
AE20 Universal Plastic Enclosure
Mounts to a single gang/double gang box, a
9 cm (3.5 in.) octagonal box, or a 10 cm (4 in.)
square box. The dimensions are 12 cm x 16 cm
x 4 cm (4.7 in. x 6.2 in. x 1.5 in.). Accommo-
dates wall tamper switches on the modules.
AE20
D203 Enclosure D203
Bosch Security Systems B.V. www.boschsecurity.com
2