2
Bosch Security Systems | 04-2003 | 3922 988 43318 en
Digital Congress Network | Installation and Operating Manual | Chapter 5 - Control using PC
en | 5-8
Connection PC to CCU
FIG 5-7 Multi-CCU System with control PC and Camera control
1
2
3
4
5
6
7
8
9
DCD
RD
TD
DTR
GND
DSR
RTS
CTS
RI
1
2
3
4
5
6
7
8
9
DCD
RD
TD
DTR
GND
DSR
RTS
CTS
RI
RS232RS232
1
2
3
4
5
6
7
8
9
DCD
RD
TD
DTR
GND
DSR
RTS
CTS
RI
1
2
3
4
5
6
7
8
9
DCD
RD
TD
DTR
GND
DSR
RTS
CTS
RI
Mult-CCU
Trunk
115V-T4A 230V -T2A
Port 1
Port 2
Rec.
Line
In
Out
In
Out
Symmetrical
In Out
Master CCU PC
RS232RS232
Control PC
OS/2 PC
EXAMPLE 2: Multi-CCU System with control PC and Camera control
Control PC requirements:
- Windows 95, 98, NT 4.0 or 2000
- Start-up software LBB 3590.
- DCN software application modules as
required.
Master CCU PC requirements:
- OS/2 version 3.0 Warp or higher
- Multi-CCU software LBB 3586
- UPS (Uninterrupted Power Supply)
recommended
Female
Female
‘Null modem ’
Video switcher (if applicable)
OUT
To next Multi-CCU
LBB 3500/35
Control PC
COM 1 COM 2
COM 1 COM 2
LBB 3511/00
Multi-CCU
PC-card
‘DIRECT’ DCN PC control
- Master CCU Port 1
- Protocol: FULL
- Baudrate: 115.2k
IMPORTANT: The LBB 3510/00 PC Network
card CANNOT be used in a PC running
Windows NT 4.0 or 2000.
Simultaneous use of the PC-Network card and
‘DIRECT’ connection is NOT possible.
NOTES:
1. When using the ‘DIRECT’ method the
functions of the PC-Network card are NOT
available (i.e. headphones and intercom).
These functions are available on the DCN
Concentus units or with the ‘Multi-purpose
connection unit’ LBB 3540/15.
2. The baud-rate setting of the Master CCU
PC port and the corresponding Control PC
port must be the same. The available baud
rate settings are 9600, 19200, 38400, 57600
and 115200. Baud rate setting on the Master
CCU PC must be set in the CCU_CFG file
(SERIAL SPEED I <baud-rate>). For more
information refer to the README.TXT file
of the Multi CCU software LBB 3586. Baud-
rate setting on the DCN Control PC must
be set in the DCN.INI file. This file can be
found in the WINDOWS or WINNT
directory.
[Server]
SerialLink=Yes
[Serial Link]
ComPort=1
Baudrate=<Baudrate>
FullProtocol=Yes
Mult-CCU
Trunk
115V-T4A 230V -T2A
Port 1
Port 2
Rec.
Line
In
Out
In
Out
Symmetrical
In Out
IN
From Multi-CCU
1 n (max.16)
9-pole D-type cable connections
75 Ohm Coax cable
Male Male
LTC 8506/00
e.g. Card encoder or
The COM-port for Master CCU control is
selected during software installation.
Select COM 1.
By default an ID-chip card encoder is connected
to COM 2. COM 2 settings can be changed in
the dcn.ini file (see Table 5-11).
serial printer etc.
Power
Code Out
Alarm
Status
Battery Low
ALLEGIANT Video System
LBB 3500/35
Male Male
For COM-port settings of the Master CCU PC
(see Chapter 5.7)
See Chapter 6. for installation details