Fujitsu ROOM AIR CONDITIONER Video Game Console User Manual


 
En-12
SWING OPERATION
Begin air conditioner operation before performing this procedure
To select Vertical airflow SWING Operation
Press the AIR FLOW DIRECTION VERTICAL SWING button .
The SWING indicator light (VERTICAL SWING) (orange) will turn on.
In this mode, the UP/DOWN air direction flaps will swing automatically to direct the
air flow both up and down.
To Stop Vertical airflow SWING Operation
Press the AIR FLOW DIRECTION VERTICAL SWING button
once again.
The SWING indicator light (VERTICAL SWING) will turn off.
Airflow direction will return to the setting before swing was begun.
Example: When set to vertical swing
SET
ENERGY
SAVE
TIME
ADJUST
TEST
RUN
ACL
SET
SWING
SWING
About Swing Operation
The range of swing is relative to the currently set airflow
direction.
Air direction range (See page 11, Fig. 8)
If the swing range is not as desired, use the remote con-
trol unit’s AIR FLOW DIRECTION VERTICAL SET button to
change the range of swing.
The SWING operation may stop temporarily when the air
conditioner’s fan is not operating, or when operating at
very low speeds.
During use of the Cooling and Dry modes, do not set the
air UP/DOWN direction flaps, in the Heating range (5 to
7) for long periods of time, since water vapor may con-
dense near the outlet louvers and drops of water may
drip from the air conditioner.
To select Horizontal airflow SWING Operation
Press the AIR FLOW DIRECTION HORIZONTAL SWING button.
The SWING indicator light (HORIZONTAL SWING) (orange) will turn on.
In this mode, the RIGHT/LEFT air direction louvers will swing automatically to direct
the airflow both right and left.
To Stop Horizontal airflow SWING Operation
Press the AIR FLOW DIRECTION HORIZONTAL SWING button
once again.
The SWING indicator light (HORIZONTAL SWING) will turn off.
Airflow direction will return to the setting before swing was begun.
Example: When set to horizontal swing
Air flow direction set
1
2
3
4
5
6
7
Range of swing
1 to 3
1 to 4
2 to 5
3 to 6
4 to 7
5 to 7
1 to 7 (All range)
SET
ENERGY
SAVE
TIME
ADJUST
TEST
RUN
ACL
SET
SWING
SWING
About Swing Operation
If the swing range is not as desired, use the remote con-
trol unit’s AIR FLOW DIRECTION HORIZONTAL SET but-
ton to change the range of swing.
The SWING operation may stop temporarily when the air
conditioner’s fan is not operating, or when operating at
very low speeds.
The range of swing is relative to the currently set airflow
direction.
Air flow direction set
1
2
3
4
5
Range of swing
1 to 5 (All range)
1 to 3
2 to 4
3 to 5
1 to 5 (All range)
Air direction range (See page 11, Fig. 9)