DC Current
Range Resolution Accuracy
40.00mA 10uA ±1.5% of rdg ±3 dgts
400.0mA 100uA
20A 10mA ±2.5% of rdg ±5 dgts
Overload Protection: 0.5A / 250V and 20A / 250V Fuse.
Maximum Input: 400mA dc or 400mA ac rms on uA / mA ranges,20A dc or
ac rms on 20A range.
AC Current
Range Resolution Accuracy
40.00mA 10uA ±1.8% of rdg ±5 dgts
400.0mA 100uA
20A 10mA ±3.0% of rdg ±7 dgts
Overload Protection: 0.5A / 250V and 20A / 250V Fuse.
Frequency Range: 50 to 60 Hz
Maximum Input: 400mA dc or 400mA ac rms on uA / mA ranges, 20A dc or
ac rms on 20A range.
Resistance
Range Resolution Accuracy
400.0Ω 0.1Ω ±1.2% of rdg ±4 dgts
4.000kΩ 1Ω ±1.0% of rdg ±2 dgts
40.00kΩ 10Ω ±1.2% of rdg ±2 dgts
400.0kΩ 100Ω
4.000MΩ 1kΩ
40.00MΩ 10kΩ ±2.0% of rdg ±3 dgts
Capacitance
Range Resolution Accuracy
4.000nF 1pF ±5.0% of rdg±50 dgts
40.00nF 10pF ±5.0% of rdg ±7 dgts
400.0nF 0.1nF ±3.0% of rdg ±5 dgts
4.000uF 1nF
40.00uF 10nF
400.0uF 0.1uF
4.000mF 0.001mF ±10% of rdg ±10 dgts
40.00mF 10.00mF
28 | MMD 540H Hybrid Multimeter | Electrical Specifi cations