Users’ Guide: Networked Receiver Controller - NRC-2.0.1 PAGE 21
11
th
October 2005 Copyright © 2005 Aegis, Inc wwww.aegis-inc.net [ph. 240-568-9006]
The LCD display symbols are listed – from highest to lowest priority, along with their meaning
in the following table.
The NRC is not configured for this channel; Configure the correct receiver for this channel.
The receiver attached to this channel is currently offline.
- Caused when the NRC is unable to communicate with the receiver via the RS-232 connection.
- Check the receiver and its NRC connections, whether the receiver is powered on, and whether the
receiver is operational or needs to be reset or needs the power cycled.
The receiver attached to this channel failed an integrity test.
- Caused when a receiver is able to communicate with the NRC, but fails to respond as expected when
tuned to provide a self-test audio tone to the NRC unit.
- Check the receiver’s RS-232 and audio connections to the NRC match and then reboot/re-power the
receiver and/or the NRC.
A client is currently connected to this channel and is receiving data from this channel.
A client is currently connected to this channel.
This channel is fully functional and available for use.
When the NRC is configured and operating correctly symbols , and will be most
often displayed.