A SERVICE OF

logo

Installation 11
MAN0708 (4/11/2008)
HYDRAULIC INSTALLATION
Keep hands and body away from pressurized
lines. Use paper or cardboard, not hands or other
body parts to check for leaks. Wear safety goggles.
Hydraulic fluid under pressure can easily penetrate
skin and will cause serious injury or death.
Make sure that all operating and service person-
nel know that if hydraulic fluid penetrates skin, it
must be surgically removed as soon as possible by
a doctor familiar with this form of injury or gan-
grene, serious injury, or death will result. CON-
TACT A PHYSICIAN IMMEDIATELY IF FLUID
ENTERS SKIN OR EYES. DO NOT DELAY.
Make sure all hydraulic hoses, fittings, and
valves are in good condition and not leaking before
starting power unit or using equipment. Check and
route hoses carefully to prevent damage. Hoses
must not be twisted, bent sharply, kinked, frayed,
pinched, or come into contact with any moving
parts. Operate moveable components through full
operational range to check clearances. Replace
any damaged hoses immediately.
Assemble Bulkhead Bracket
1. Connect bulkhead adapter (3) to bulkhead
bracket (19) and secure using hex nut provided
with adapter.
2. Attach female quick coupler (16) and elbow (13)
to bulkhead bracket (19) as shown in Figure 17.
3. Remove lower right bolt from top link bracket.
4. Place bulkhead bracket over top link bracket and
secure into position using hardware previously
removed. See Figure 17.
3. 1009495 Adapter, 3/8 NPTM x 9/16 JICF
13. 38604 Elbow, 9/16 JICM x 9/16 JICF 90°
16. 64299 Quick coupler, female 3/8
19. 1022141 Bulkhead bracket
Figure 17. Bulkhead Bracket Installed
Figure 18. Bulkhead Bracket Assembly
DP18