RANGE HOOD BLOWER ORIENTATION
.I
I
(TOP OF HOODI
NOTE: Before reinstalling the blower Assembly, check the
damper for free operation. Open the damper blade and
check for any restrictions in the duct system. Check
installation instructions for proper duct sizing.
Correct Blower orientation is imperative. Incorrect
installation will drastically cut air flow and cause Blower to
run at maximum RPM regardless of motor speed control
setting.
BLOWER DISCHARGE -
LOCATE AT DIS-
CHARGE VENT IN
TOP OF HOOD
,,/ THIS SURFACE
TO
REAR
VERTICAL DISCHARGE:
1. Figure 7 shows the proper Blower Assembly orientation
for vertical discharge.
2. From the blower position shown in Figure 7. lift the
Blower Assembly vertically into mounting position.
3. The 3” blower discharge surface should now be flush
against top of hood. This will allow proper air flow from the
blower through the top vent. (The wider 5” surface will be to
the rear.)
FIGURE 7
VERTICAL DISCHARGE
HORIZONTAL DISCHARGE:
1. Figure 8 shows the proper Blower Assembly orientation
for horizontal discharge.
LOCATE AT OIS-
CHARGE VENT
IN SEAR OF HOOD
2. From the Blower position shown in Figure 8. lift the
blower Assembly vertically into position.
3. The 3” Blower discharge surface should now’ be flush
against rear of hood. This will allow proper air flow from the
Blower through the rear vent. (the wider 5” surface will be to
the top.)
FIGURE 8
HORIZONTAL DISCHARGE