2. Soft Start Cycle (SS-Low / SS-Med)
Once the fi re is lit:
The appliance moves into the low soft-start cycle as it
continues to build the fi re
More fuel will be added
As the fi re builds, the appliance will change to medium
soft-start mode
The heating cycle begins
3. Heating Cycle ( Auto / Man - L, ML, M, MH, H)
There are two choices in the Automatic / Manual menu of
how your appliance will operate:
Automatic Mode
The wall control will turn the heat output level up or down
depending on how far the room temperature is from the
desired temperature
The digital display will read AUTO:M, i.e. automatic-me-
dium level
As the room temperature approaches the desired tem-
perature, the appliance will turn down to lower settings
When the home reaches your set temperature, the appli-
ance will go into the shutdown cycle
Manual Mode
Set the heat output setting from the main screen
The right bottom button will read HEAT OUTPUT
You can operate the appliance from any of the 5 levels
On the lowest level (MAN: L) the appliance will stay on
longer, burn less fuel per hour, and will take longer to
bring the home up to your desired temperature
• On the highest setting (MAN:H) the appliance will burn
more fuel per hour, and bring your home up to tempera-
ture more quickly
In Manual mode the heat output does not change but
will stay at the setting you chose until the comfort level
is reached (meaning the thermostat has been satisfi ed).
Turn to OFF to stop operation.
4. Shutdown Cycle
Once your home has reached your set temperature:
Appliance will stop feeding fuel and allow the fi re to dimin-
ish
Convection blower will continue to run until the appliance
cools to appropriate temperature
Appliance will begin the auto-clean cycle
5. Auto-Clean Cycle
The fi repot auto-clean system will cycle:
When the appliance is fi rst plugged in
When the house reaches temperature and the appliance
shuts down
At prescribed intervals, depending on the type of fuel se-
lected
When starting up after an electrical interruption
If your appliance is running and the auto-clean cycle is initi-
ated, the appliance will revert to shutdown cycle.
The fl oor of the fi repot will open and dump the ash into
the ash pan
It takes approximately 2 minutes to complete the auto-
clean cycle
The fl oor will then shut, and if the thermostat is still call-
ing for heat, the fi re will start again
During this auto-clean cycle, the convection blower may
continue to run. The combustion blower will continue to
run.
Additional Screen Messages:
READY It is telling you that the home is up to temperature
and doesn’t need any heat.
- - - - - The screen will show 5 dashes when the wall
control and the control board are NOT communicating with
each other. Check that the wiring on the thermostat is prop-
erly connected.
MAINTENANCE BURN This indicates the appliance is
operating on battery backup, prior to the auto-clean. The
maintenance burn will keep the system from shutting down
as the appliance will not automatically re-light in battery
back-up mode.
OFF The AUTO/MANUAL SETTING screen has been set
to OFF. Set the appliance to OFF when performing periodic
maintenance to prevent an unexpected startup.
BLANK SCREEN The ON/OFF switch may in OFF posi-
tion. Turn to ON position.
Tested and approved for wood pellets, shelled fi eld
corn, wheat and black oil sunfl ower seeds. Burning
of any other type of fuel voids your warranty.
CAUTION