IBM eServer BladeCenter Fibre Channel Switch Module
Timeout Values
QL
OGIC SWITCH INTEROPERABILITY GUIDE PAGE 131
V
ERSION 1.0, MARCH 2003
3. From the Switch Properties—IBM BladeCenter SAN Utility dialog box, verify that R_A_TOV
is set to 10000 and E_D_TOV is set to 2000. If the settings are not correct, proceed to step 4.
If the settings are correct, no changes need to be made; proceed to the next appropriate
section.
4. From the Switch Properties—IBM BladeCenter SAN Utility dialog box Administrative
State list, select offline. Click OK.
5. Re-enter the Switch Properties—IBM BladeCenter SAN Utility dialog box (see step 2). DO
the following:
a. In the R_A_TOV box, enter 10000.
b. In the E_D_TOV box, enter 2000.
c. Click OK.
6. Re-enter the Switch Properties—IBM BladeCenter SAN Utility dialog box (see step 2). In
the Administrative State list, select Online. Click OK.