![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/a/41/a418a6f8-9fcb-4bab-b093-34fc57317cbe/a418a6f8-9fcb-4bab-b093-34fc57317cbe-bg9e.png)
A – Command Line Interface
Set Setup Command
A-44 59022-06 A
Q
Examples The following is an example of the Set Setup SNMP command:
SANbox2 #> admin start
SANbox2 (admin) #> set setup snmp
A list of attributes with formatting and current values will follow.
Enter a new value or simply press the ENTER key to accept the current value.
If you wish to terminate this process before reaching the end of the list
press 'q' or 'Q' and the ENTER key to do so.
Trap Severity Options
---------------------
unknown, emergency, alert, critical, error, warning, notify, info, debug, mark
Contact (string, max=32 chars) [<sysContact undefined]
AdminTimeout Specifies the amount of time in minutes the switch
waits before terminating an idle Admin session. Zero
(0) disables the time out threshold. The default is 30,
the maximum is 1440.
TempMonitoringWarning Warning temperature threshold in °C above which a
warning condition alarm is generated. The default is
65 °C.
TempMonitoringFailure Failure temperature threshold in °C above which a
failure condition alarm is generated. The default is 70
°C.
TempFailurePortShutdown Enables (True) or disables (False) the switch’s ability
to place all ports down when the internal temperature
exceeds the failure threshold. The default is False.
SecurityEnabled Enables (True) or disables (False) the enforcement of
account names and passwords. The default is False.
LocalLogEnabled Enables (True) or disables (False) the saving of log
information on the switch. The default is True.
RemoteLogEnabled Enables (True) or disables (False) the recording of
the switch event log on a remote host that supports
the syslog protocol. The default is False.
RemoteLogHostAddress The IP address of the host that will receive the switch
event log information if remote logging is enabled.
The default is 10.0.0.254.
Table A-14. System Configuration Settings (Continued)
Entry Description