6
A. Connect the water pump discharge to the water
cooler using the supplied hose, hose elbow and
hose mender. The hoses will need to travel
through (holes must be drilled) or under the
radiator core support.
B. Connect the open fitting on the water cooler to the
bottom fitting on the charge cooler using the sup-
plied hose and two hose elbows and hose menders
if needed for smooth routing.
C. Connect the top fitting on the CAC to the upper
fitting on the reservoir using a 90ยบ hose elbow.
(See Fig. 4-a)
D. Install and tighten the supplied plastic ratchet
clamps on all hose connections.
E. Remove the reservoir cap and fill system with
25%/75% coolant/water mix.
F. Make sure that all wires and hoses are routed
away from hot, moving or sharp objects.
G. Key on and verify coolant circulation through the
system. Check for leaks.
Section 6
Plumbing and Bleeding System
6. Plumbing and Bleeding System
Fig. 6-a
NOTE: Someof the supplied
fittings and hoses may not
be used. Take special care
not to kink the hoses
by using the ones that
best fit your application.
*** NOTE ***
If supercharger boost is increased a larg-
er bypass valve may be required to
reduce compressor surge.