A SERVICE OF

logo

ACCULINK 316x DSU/CSU
H-16 January 1997 3160-A2-GB21-50
General Options
Front Panel
Equivalent
Value (Default in Bold)
Generate Yellow Alarm Signals Gen Yellow Enable, Disable
Initial Self Test Self-Test Enable, Disable
Primary Clock Source Clock Src Network, DTE, Internal, External, Port 1
External Clock Rate (KHz) Clock Rate 2048, 1544, 8
Test Timeout Tst Timeout Enable, Disable
Test Duration Tst Duration 1–120 (Default = 10)
User Interface:
Front Panel Options
Front Panel
Equivalent
Value (Default in Bold)
Front Panel Access FP Access Enable, Disable
Front Panel Pass-Through FP Pass Enable, Disable
User Interface:
Communication Port Options
Front Panel
Equivalent
Value (Default in Bold)
Port Use Com Use Mgmt, ASCII, Daisy, Terminal
Port Type Com Type Asynchronous, Synchronous
Clock Source Com Clk Internal, External
Data Rate Com Rate 1.2, 2.4, 4.8, 9.6, 14.4, 19.2, 38.4
Character Length Char Length 7, 8
Parity CParity None, Even, Odd
Stop Bits CStop Bits 1, 1.5, 2
Ignore Control Leads Ignore DTR Disable, DTR
Password Required Password Enable, Disable
Inactivity Timeout CmInActTm Enable, Disable
Disconnect Time CmDiscTm 1–60 (Default = 5)