2. Classic Slave
Classic Slave is the designation of the second FX in a two-inverter, split-phase system that produces
240 VAC without using an FW-X240 Auto Transformer.
This FX is plugged into Port 02 of the HUB.
OB Slave L1 and OB Slave L2 designations are used in OutBack Parallel Stacking or OutBack Series/
Parallel stacking
3. OB Slave L1
In an OutBack Parallel single-phase system, all the Slave FXs on a single 120 VAC leg are designated
OB Slave L1.
In an OutBack Series split-phase system, which will include an FW-X240 or PSX-240 Auto Transformer,
any FX that runs in parallel to the Master FX is designated OB Slave L1. These FXs must be plugged
into the lowest HUB Ports.
The OB Slave L1 Stacking is typically used for an entirely o -grid application such as a cabin that
does not require 240 volts.
4. OB Slave L2
In an OutBack Series split-phase system, any Slave FX that runs in series with the Master FX is
designated OB Slave L2.
5. 3ph Master
In 3-phase stacking, the Master FX is designated as 3ph Master.
3ph Master and 3ph Slave designation are used in OutBack 3-phase stacking.
6. 3ph Slave
• In 3-phase stacking, each of the Slave FXs, which should be plugged into HUB
Ports 02 (phase B) and 03 (phase C) respectively, is designated as 3ph Slave.
• When the HUB jumper is set between Port 02 and Port 03, the HUB identifies a
phase for each Slave FX.
Stacking Phases/Assigning FX Status (in order):
1. 1-2ph Master*
2. Classic Slave
3. OB Slave L1
4. OB Slave L-2
5. 3ph Master
6. 3ph Slave
*GTVX and GVFX models show “Master” on the screen