TROUBLESHOOTING & REPAIR
F-32 F-32
V205-T AC/DC
MAIN INVERTER BOARD “UPFR” SECTION TEST (continued)
TEST PROCEDURE
1. Remove input power to the V205-T machine.
2. Using a phillips head screwdriver, remove the
case wraparound cover.
3. Perform the Capacitor Discharge
Procedure detailed earlier in this section.
4. Locate the UPFR section on the main board
and associated plugs. Do not remove
plugs from the board. See Figure F.14.
5. Carefully apply the correct input voltage to
the V205-T and check for the correct sec-
ondary voltages per tables F.10 & F11.
Voltage readings were taken with a Fluke
RMS meter. See Figure F.15 for joint loca-
tions.
FIGURE F.14 UPFR LOCATION ON MAIN BOARD