A-4
INSTALLATION
POWER WAVE® C300
A-4
INPUT CONNECTION
Only a qualified electrician should
connect the input leads to the
POWER WAVE® C300. Connections
should be made in accordance with
all local and national electrical
codes and the connection diagram located on the
inside of the reconnect access door of the
machine. Failure to do so may result in bodily
injury or death.
------------------------------------------------------------------------
A 15 ft. power cord is provided and wired into the
machine.
For Single Phase Input
Connect green lead to ground per National Electrical
Code.
Connect black and white leads to power.
Wrap red lead with tape to provide 600V insulation.
For Three Phase Input
Connect green lead to ground per National Electric
Code.
Connect black, red and white leads to power.
INPUT FUSE AND SUPPLY WIRE
CONSIDERATIONS
Refer to Specification Section for recommended fuse,
wire sizes and type of the copper wires. Fuse the
input circuit with the recommended super lag fuse or
delay type breakers (also called "inverse time" or
"thermal/magnetic" circuit breakers). Choose input
and grounding wire size according to local or national
electrical codes. Using input wire sizes, fuses or cir-
cuit breakers smaller than recommended may result
in "nuisance" shut-offs from welder inrush currents,
even if the machine is not being used at high cur-
rents.
INPUT VOLTAGE SELECTION
The POWER WAVE® C300 automatically adjusts to
work with different input voltages. No reconnect
switches settings are required.
The POWER WAVE® C300 ON/OFF
switch is not intended as a service
disconnect for this equipment. Only
a qualified electrician should con-
nect the input leads to the POWER
WAVE® C300. Connections should be made in
accordance with all local and national electrical
codes and the connection diagram located on the
inside of the reconnect access door of the
machine. Failure to do so may result in bodily
injury or death.
------------------------------------------------------------------------
POWER CORD REPLACEMENT
Only a qualified electrician should
connect the input leads to the
POWER WAVE® C300. Connections
should be made in accordance with
all local and national electrical
codes and the connection diagram located on the
inside of the reconnect access door of the
machine. Failure to do so may result in bodily
injury or death.
------------------------------------------------------------------------
If the input power cord is damaged or needs to be
replaced an input power connection block is located
in the access panel under the wire spool.
ALWAYS CONNECT THE POWERWAVE GROUND-
ING LUG (LOCATED INSIDE THE ACCESS PANEL)
TO A PROPER SAFETY (EARTH) GROUND.
FIGURE A.1
WARNING
WARNING
WARNING
HINGED COVER
GROUNDING LUG
TOP VIEW DETAIL OF
INPUT CONNECTION