Rotate the WFS knob until the desired parameter is
displayed.
CV/CC Mode:
WFS Units:
2. Activate and release the GAS PURGE switch to
select the parameter. The present value will then
display in the right hand side of the display.
Example:
3. Rotate the WFS knob to change the parameter set-
ting.
CV/CC Mode:
• "CU" for Constant Voltage power sources
• "CC" for Constant Current power sources
WFS Units:
• "US" for in/min
• "Eur" for m/min
4. Press the GAS PURGE switch to save the setting.
The LN-15 will then return to the original "Press
Spin" mode in step 1.
5. To exit the "Press Spin" set-up mode, turn off power
to the LN-15, or simply wait 15 seconds and the
LN-15 will enter normal operation.
WFS
SPRING TENSION ARM
The pressure arm controls the amount of force the drive
rolls exert on the wire. Proper adjustment of both pres-
sure arm gives the best welding performance. For best
results, set both pressure arms to the same value.
Set the pressure arm as follows (See Figure B.2a):
Aluminum wires between 1 and 3
Cored wires between 3 and 4
Steel, Stainless wires between 4 and 6
Figure B.2a
FLOWMETER
SPRING
TENSION
ARM
COLD FEED/
GAS PURGE
SWITCH
2 STEP/TRIGGER
INTERLOCK
SWITCH
SPINDLE
BRAKE
INTERNAL CONTROLS (Figure B.2)
ALUMINUM
OUTERSHIELD
METALSHIELD
IN NERSHIELD
STEEL
STAIN L ESS
CORED WIRES
SOLID WIRES
6
1
3
2
5
4