MAINTENANCE
Removal of BioClip plug (Combi)
To change a Combi unit from BioClip function to
cutting unit with rear ejection, remove the BioClip
plug located under the unit with three screws.
1. Put the unit in the service position, see Placing
in the service position.
2. Remove the three screws holding the BioClip
plug, and remove the plug.
3. Tip: Fit three full-thread screws M8x15 mm in
the screw holes to protect the threads.
4. Replace the unit in normal position.
Fit the BioClip plug in the reverse order.
Cutting unit models
The following versions of cutting units can be used
on this type of machine:
Cutting unit with rear ejection 97 and 120
Removal of BioClip plug