Drawing No. Sheet No. Revision 5
K6602906 16/46 2003/6/12
4.2 Power supply current
Fig 4.1 Current transition for +12V
Note: A retry Spin-up operation may be attempted during the Start up process.
4.3 Spindle Start and Stop
4.3.1 Start and Stop Time
Table 4.2 Start and Stop time
Item Typical unit
Start 25 Note 1 s
Stop 25 Note 2 s
Note 1. Start time means that the time of becoming ready, after DC power has been
applied in the case of Enable Auto Start mode, or after Start Unit command
(immed=0) has accepted in other case. If internal retry is executed during the Start-
up operation, the Start time may exceed typical value. It is recommended to have 60
seconds for the Start time. In the case of a spindle start-up failure, the time of an
internal retry operation is 130 seconds maximum.
Note 2. Beginning of stop time is basically decided by +12v DC power off.
In case of +5v DC power off only, stop time is 65sec(typ).
Do not move the drive until motor stop completely.
Stop time means that the time to stop the spindle rotation, after DC power has
been shut off, or after stop operation has started.
Caution
+12V Current
[A]
1.0
0
2.0
3.0
Time [s]
0
2
4 6 8 10 12 14 16 18 20
T0
T1
T2
T3
T4
T1 : Accept start unit command or Auto Spin-up
T4 :Ready
T0 : Power on
T2-T3: Servo initialize
T3-T4: Upload Code etc.
T1-T4: Start up
T0-T1: Power up
T1-T2: Spin-up
Peak