
EPSON AcuLaser C1100 Revision B
OPERATING PRINCIPLES Control 112
Control of Toner Cartridge
1. Detection of Empty status
The judgement of the Empty status of Toner Cartridges is made based on toner
patch density values (read by ADC sensor). When toner patch density is extremely
low, the printer executes forced supply of toner (Admix operation), and it judges
that the cartridge is empty if the density of toner patches created after the forced
supply is still low.
2. Reset of the Empty status
The printer judges that the empty Toner Cartridge is replaced with a new one when
the power is turned off and back on, and the cover is opened and then closed
during the Empty status. Then the printer executes forced supply of toner from the
newly attached cartridge.
Figure 2-56. PCDC Mechanism
ROS ASSY
Toner Cartridge
Developer Assy
Dispense
Clutch
MOT ASSY MAG
Auger
(MCU PWB)
Leg_Sec06_062FB